From an email from Susan Mustafa and based on http://lclpioneer.wordpress.com/2011/05/02/getting-a-3m-self-check-to-work-with-koha/ (dead link)
1. Login to 3M Self Check System Administration web page. 2. Select the network menu 3. Scroll down to Host Communications and change 1. Communication Type Telnet 2. TCP Port 8041 3. Host Name or IP 75.101.142.135 (This is the test SIP server IP) 4. Scroll down to the 3M Command Center (CIMS) and click Save Changes 5. Scroll down to Send/Expect Scripts and click Edit Login Send/Expect
(in 2 and 3 below replace sipuserid with your SIP USER ID and sipuserpassword with your SIP USER PASSWORD , see below)
No double quotes --
1. Click Menu+ 1. Send String (leave blank) 2. Expect String login: 3. Timeout 30 4. Retries 3 5. Click Add 2. Click Menu+ 1. Send String sipuserid\r 2. Expect String password: 3. Timeout 30 4. Retries 3 5. Click Add 3. Click Menu+ 1. Send String sipuserpassword\r 2. Expect String Login OK. Initiating SIP (note 2 spaces after OK. ) 3. Timeout 30 4. Retries (or 3 works as well) 5. Click Add